Description
The F014 is a local flow rate indicator and totalizer with a scaled pulse output that retransmits the accumulated total to remote systems. The pulse scale is fully configurable, allowing flexible integration with downstream instrumentation. Totals are backed up in EEPROM memory, and engineering units are configured on-screen.
Features
- Simultaneous display of flow rate, resettable running total, and non-resettable accumulated total
- Scaled pulse output reflecting accumulated total; configurable pulse scale (e.g. one pulse per 3.25 GAL)
- Selectable large digit mode: flow rate or total displayed at 17 mm (0.67″”) height
- Flow rate: 7 digits at 17 mm (0.67″”) or 8 mm (0.31″”)
- Running total: 7 digits at 17 mm (0.67″”); resettable via double CLEAR button press
- Accumulated total: 11 digits at 8 mm (0.31″”); non-resettable
- Separate on-screen engineering units for flow rate and total
- Flow rate units: mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P, or none; time units: /sec, /min, /hour, /day
- Total units: mL, L, m³, GAL, USGAL, kg, lb, bbl, or none
- LED backlight with adjustable intensity
- Auto backup of settings and running totals in EEPROM memory
- Intrinsically safe: ATEX, IECEx, and CSA C-US certified
- Explosion-proof option available (ATEX/IECEx)
- Available in GRP, aluminium, or high-grade stainless steel enclosure
- Ambient temperature: −40 to +70 °C (−40 to +158 °F)
- Various accessories available
Applications
- Flow measurement requiring local display and totalizer retransmission to remote systems
- Harsh outdoor environments: rain, snow, sand, salt atmosphere
- Oil and gas, chemical, and process plant field installations
- Safe and hazardous area installations
Certifications
- ATEX — Gas (IS): II 1 G Ex ia IIC T4 Ga
- ATEX — Dust (IS): II 1 D Ex ia IIIC T200 100 °C Da
- IECEx — Gas (IS): Ex ia IIC T4 Ga
- IECEx — Dust (IS): Ex ia IIIC T200 100 °C Da
- CSA C-US (IS): Class I/II/III Div 1 Grp A–G T4 · Class I Zone 0 AEx ia IIC T4 Ga
- ATEX/IECEx — Gas (Ex-proof): II 2 G Ex db IIB+H2 T5 Gb
- ATEX/IECEx — Dust (Ex-proof): II 2 D Ex tb IIIC T80 °C Db